Power Series Products / Cable Joint Protection Shell
Stainless steel fireproof and explosion-proof box for cable intermediate joints
Model:

1 / 2

1

2
Description
The main material of this product is high-strength 304 stainless steel, and the inner surface is lined with flexible fireproof cotton (wrapped in aluminum foil). The main body of the intermediate joint is wrapped with self-adhesive fire-resistant anti-arc tape; the gaps between the inner ends of the explosion-proof box and the cable are stuffed with intumescent flame-retardant flexible fireproof putty; then intumescent explosion-proof fire-retardant packs are placed inside the explosion-proof box; together with the protection of the external high-strength flame-retardant explosion-proof box, the overall structure adopts a three-layer fire and explosion protection approach, thereby achieving an overall fire and explosion protection function. The product has passed the verification and testing for the explosion-proof certificate by the National Quality Supervision and Inspection Center for Explosion-Proof Electrical Products, and meets the requirements of GB 3836.1-2010 "Explosive atmospheres – Part 1: Equipment – General requirements" and GB 3836.3-2010 "Explosive atmospheres – Part 3: Equipment protected by increased safety 'e'". This product is mainly used in power cable intermediate joints: in the event of a fault, it confines the high-pressure airflow, flames, and fragments generated by the explosion inside the explosion-proof box, and also prevents the fire spread and explosion impact caused by the fault from causing large-scale damage to other power facilities. The fireproof and explosion-proof box is installed outside the intermediate joint. During normal operation, it protects the intermediate joint from external force damage and provides a certain mechanical protection effect, while also preventing the spread of combustion from surrounding power facilities from damaging the intermediate joint. When the intermediate joint catches fire or explodes due to an accidental fault, the box can provide fire and explosion protection, and can also provide a certain protective isolation effect on other cables or surrounding equipment in the cable trench. The intermediate joint fireproof and explosion-proof box consists of two halves that enclose the joint, making on-site installation convenient. The two sides of the explosion-proof box are flanged.
Features
- This product's main material is high-strength 304 stainless steel, with the inner surface laminated with flexible fireproof cotton (wrapped in aluminum foil). The main body of the intermediate joint is wrapped with self-adhesive fireproof and anti-arc tape, and the gaps between the inner ends of the explosion-proof box and the cable are stuffed with intumescent flame-retardant flexible fireproof putty; in addition, intumescent explosion-proof firestop packs are placed inside the explosion-proof box, and with the protection of the external high-strength flame-retardant explosion-proof box, the overall structure adopts a three-layer fireproof and explosion-proof configuration, thereby achieving integrated fire and explosion protection. The product has passed the verification and testing for the explosion-proof certificate by the National Center for Quality Supervision and Inspection of Explosion-proof Electrical Products, and meets the requirements of standards GB 3836.1-2010 "Explosive atmospheres – Part 1: Equipment – General requirements" and GB 3836.3-2010 "Explosive atmospheres – Part 3: Equipment protected by increased safety 'e'". This product is mainly used for power cable intermediate joints; when a fault occurs, it confines the high-pressure airflow, flames, and debris generated by the explosion within the explosion-proof box, and also prevents the fire spread and explosion impact caused by the fault from causing large-scale damage to other power facilities. The fireproof and explosion-proof box is installed outside the intermediate joint; during normal operation, it protects the intermediate joint from external force damage and provides a certain mechanical protection effect, while also preventing the joint from being damaged by fire spreading from surrounding power facilities. When the intermediate joint catches fire or explodes due to an accidental fault, it provides fireproof and explosion-proof functions, and also offers a certain protective isolation effect for other cables or surrounding equipment in the cable trench. The intermediate joint fireproof and explosion-proof box is made of two halves that clamp together, making on-site installation convenient. The flange joints on both sides of the box are fitted with sealing strips, and waterproof tape is wrapped around both ends, providing a certain degree of waterproof performance. Product features: 1. The three-layer integrated fireproof and explosion-proof structure provides all-around protection for cable joints. 2. The main body of the intermediate joint is wrapped with self-adhesive fireproof and anti-arc tape, protecting the intermediate joint from external flame burns and also preventing the flames caused by breakdown combustion of the joint from spreading. 3. Intumescent flame-retardant explosion-proof firestop packs are placed inside the box to buffer lateral shock waves caused by an explosion and prevent further fire spread. The gaps between the inner ends of the box and the cable are filled with flexible fireproof putty, which buffers longitudinal shock waves caused by an explosion and prevents the fire from further spreading to the cable. 4. The high-strength explosion-proof box housing confines the high-pressure airflow, flames, and debris generated by the explosion within the box, while preventing fire spread and explosion impact caused by the fault from causing large-scale damage to other power facilities, also preventing the intermediate joint from being damaged by fire spreading from surrounding power facilities, and ensuring pedestrian safety.
Specifications
1Lightning impulse withstand voltage test (75 kV peak) / No breakdown of the sample
2Explosion test (12 kV, 20 kA, 0.1 s) / No damage or cracking of the sample
3Structural inspection / GB3836.1 GB3836.3 / Relevant clauses / Complete machine / 1) The nameplate and warning plate comply with the standard requirements. 2) Earthing and marking comply with the standard requirements. 3) The structure complies with the standard requirements.
4Impact test / GB3836.1 26.4 / Enclosure / The enclosure withstands the impact energy generated by a test object of mass 1.0 kg falling vertically from a height of 0.7 m; no damage occurs
5Temperature test / GB3836.1 26.5.1 / Complete machine / The maximum surface temperature of the sample enclosure, cable conductor connection parts, cable encapsulation points, and sealing gaskets complies with the standard requirements
6Enclosure protection rating test / GB3836.1 26.4.5 / Complete machine / Level 6 dust test: Place the sample in a dust chamber, connect the exhaust pipe, with a negative pressure less than 2 kPa, test for 2 h; after the test, check that no dust has entered the sample. Level 6 water test: Use a Φ12.5 mm nozzle test device, with a total flow rate of 100 L/min, test for 3 min; after the test, check that no water has entered the sample.
Similar Products

1 / 2

1

2
Features
- This product's main material is high-strength 304 stainless steel, with the inner surface laminated with flexible fireproof cotton (wrapped in aluminum foil). The main body of the intermediate joint is wrapped with self-adhesive fireproof and anti-arc tape, and the gaps between the inner ends of the explosion-proof box and the cable are stuffed with intumescent flame-retardant flexible fireproof putty; in addition, intumescent explosion-proof firestop packs are placed inside the explosion-proof box, and with the protection of the external high-strength flame-retardant explosion-proof box, the overall structure adopts a three-layer fireproof and explosion-proof configuration, thereby achieving integrated fire and explosion protection. The product has passed the verification and testing for the explosion-proof certificate by the National Center for Quality Supervision and Inspection of Explosion-proof Electrical Products, and meets the requirements of standards GB 3836.1-2010 "Explosive atmospheres – Part 1: Equipment – General requirements" and GB 3836.3-2010 "Explosive atmospheres – Part 3: Equipment protected by increased safety 'e'". This product is mainly used for power cable intermediate joints; when a fault occurs, it confines the high-pressure airflow, flames, and debris generated by the explosion within the explosion-proof box, and also prevents the fire spread and explosion impact caused by the fault from causing large-scale damage to other power facilities. The fireproof and explosion-proof box is installed outside the intermediate joint; during normal operation, it protects the intermediate joint from external force damage and provides a certain mechanical protection effect, while also preventing the joint from being damaged by fire spreading from surrounding power facilities. When the intermediate joint catches fire or explodes due to an accidental fault, it provides fireproof and explosion-proof functions, and also offers a certain protective isolation effect for other cables or surrounding equipment in the cable trench. The intermediate joint fireproof and explosion-proof box is made of two halves that clamp together, making on-site installation convenient. The flange joints on both sides of the box are fitted with sealing strips, and waterproof tape is wrapped around both ends, providing a certain degree of waterproof performance. Product features: 1. The three-layer integrated fireproof and explosion-proof structure provides all-around protection for cable joints. 2. The main body of the intermediate joint is wrapped with self-adhesive fireproof and anti-arc tape, protecting the intermediate joint from external flame burns and also preventing the flames caused by breakdown combustion of the joint from spreading. 3. Intumescent flame-retardant explosion-proof firestop packs are placed inside the box to buffer lateral shock waves caused by an explosion and prevent further fire spread. The gaps between the inner ends of the box and the cable are filled with flexible fireproof putty, which buffers longitudinal shock waves caused by an explosion and prevents the fire from further spreading to the cable. 4. The high-strength explosion-proof box housing confines the high-pressure airflow, flames, and debris generated by the explosion within the box, while preventing fire spread and explosion impact caused by the fault from causing large-scale damage to other power facilities, also preventing the intermediate joint from being damaged by fire spreading from surrounding power facilities, and ensuring pedestrian safety.