This model of bushing is structurally designed in accordance with standard EN 50181 and also complies with American standard IEEE 386. The shed end can be connected to a busbar for air insulation, while the other end can be fitted with a plug or sealed in high-voltage insulating oil for use as an equipment lead. It is suitable for operation of high-voltage equipment at altitudes up to and including 4000 m, and is commonly used in photovoltaic and wind power applications. The grounding hole on the flange surface allows connection of a voltage presence indicator.
Features
This model bushing is structurally designed in accordance with standard EN 50181 and also complies with American standard IEEE 386. The shed end can be connected to busbars for air-insulated use, while the other end can be connected to plugs or sealed in high-voltage insulating oil for use as equipment lead wires. It is suitable for high-voltage equipment operation at altitudes up to 4000 meters, and is widely used in photovoltaic and wind power applications. The grounding hole on the flange face can be connected to a voltage indicator.
Specifications
Rated voltage (kV)Rated current (A) / Air tightness (Pa·m3/s) / X-ray flaw detection / Withstand voltage / Partial discharge
35 kV630 A / ≤1.0×10^-8 Pa·m3/s / No porosity or impurities / 95 kV 1 min / ≤10 pC
This model bushing is structurally designed in accordance with standard EN 50181 and also complies with American standard IEEE 386. The shed end can be connected to busbars for air-insulated use, while the other end can be connected to plugs or sealed in high-voltage insulating oil for use as equipment lead wires. It is suitable for high-voltage equipment operation at altitudes up to 4000 meters, and is widely used in photovoltaic and wind power applications. The grounding hole on the flange face can be connected to a voltage indicator.
Specifications
Rated voltage (kV)Rated current (A) / Air tightness (Pa·m3/s) / X-ray flaw detection / Withstand voltage / Partial discharge
35 kV630 A / ≤1.0×10^-8 Pa·m3/s / No porosity or impurities / 95 kV 1 min / ≤10 pC
This model of bushing is structurally designed in accordance with standard EN 50181 and also complies with American standard IEEE 386. The shed end can be connected to a busbar for air insulation, while the other end can be fitted with a plug or sealed in high-voltage insulating oil for use as an equipment lead. It is suitable for operation of high-voltage equipment at altitudes up to and including 4000 m, and is commonly used in photovoltaic and wind power applications. The grounding hole on the flange surface allows connection of a voltage presence indicator.